TSL‑1064‑18‑56‑V1 Telecentric F-theta Lens,18×18mm Scan Field, f=56mm

TSL‑1064‑18‑56‑V1 Telecentric F-theta Lens,18×18mm Scan Field, f=56mm

Telecentric F-Theta Scan lens is a special type of lens system whereby the deflected off-axial laser beam can be perpendicularly focused to work piece as similar to the on-axial focusing beam. The advantage of the telecentric scan lens is that it is able to flatten the field curvature to the least distortion and yet offering superb spot quality throughout the scan field. For high powered laser and ultrafast laser source, we offer TSL-Q Series Telecentric F-Theta Scan Lens to minimize thermal lensing and focal shift.

Part No.: TSL-1064-18-56

EFL: 56.0 mm

Scan Field: 18×18 mm

Input Beam Φ (1/e²): 10.0 mm

Thread: M39x1

WD: 59.8 mm

Window Dia×Thk: 40×2 mm


Product Detail

Product Tags

Quartz Material Series
355nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (mm) Telecentric Angle (mm) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-355-8-32-D10-V1 32 8*8 10 ±10.2 1 M79*1 60.3 16.3
TSL-355-18-56 56 18*18 6 ±15 4 M85*1 88.84 73.84
TSL-355-35-80 80 35*35 6 ±19 3 M55*1 155.56 104.46
TSL-355-35-100 100 35*35 10 ±14.4 4 M55*1 203.47 131.95
TSL-355-50-103-V1 103 50*50 9 ±20.2 2.5 M85*1 179 135.8
TSL-355-60-135Q-D12 135 60*60 12 ±18.5 1.2 M85*1 259 185
TSL-355-63-109-V1 109 63*63 6 ±24.2 1.5 M85*1 228.4 146.3
TSL-355-90-163Q-D10-V1 163 90*90 10 ±25 4.3 M85*1 301.56 214.76
TSL-355-100-170Q-D10-V1 170 100*100 10 ±25 5 M85*1 318.9 238.1
TSL-355-120-210Q-D14 210 120*120 14 ±24 3.1 M79*1 463.31 300.48
TSL-355-160-330Q-D15 330 160*160 15 ±19.6 3.9 Φ85 (Flange Mount) 672.61 454.86
343nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (mm) Telecentric Angle (mm) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-343-180-330Q-D15-V1 330 180*180 15 ±22.2 3.9 M85*1 672.61 454.86
TSL-343-190-330Q-D14 330 190*190 14 ±24.7 4 M85*1/6-Φ6.5 695.04 441.54
532nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-532-10-56Q-D20 56 10*10 20 ±7.3 1.1 M55*1 90.05 21.48
TSL-515-30-80-D12 80 30*30 12 ±15.6 1.7 M55*1 169.32 80.6
TSL-532-40-100Q 100 40*40 10 ±25 1 M85*1 190.8 135.76
TSL-532-52-105Q-D10 105 52*52 10 ±19.2 3 M79*1 209.3 131.1
TSL-532-90-163Q 163 90*90 10 ±25 4.8 M85*1 297.2 219.5
1064nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-1064-7-50Q-D15 50 7*7 15 ±5.7 2.3 M85*1 85.69 60.67
TSL-1064-10-56Q-D20 56 10*10 20 ±7.2 1 M55*1 88.87 23.87
TSL-1064-20-70Q-D14 70 20*20 14 ±12 2.4 M55*1 158.46 78.87
TSL-1064-50-100Q-D10 100 50*50 10 ±21 1.9 M85*1 202.11 126.11
TSL-1064-50-100Q-D15 100 50*50 15 ±21.3 3 M85*1 251 131
TSL-1064-55-100Q 100 55*55 15 ±25 3 M85*1 189.51 120.79
TSL-1064-80-180Q-D10 180 80*80 10 ±25 2.6 M85*1 335.03 259.43
TSL-1064-85-167Q-D20 167 85*85 20 ±21.2 3.5 M85*1 330.88 226.33
TSL-1064-90-163Q-D15-V2 163 90*90 15 ±23 4.5 M85*1 299.86 211.06
TSL-1064-100-170Q-D10 170 100*100 10 ±24.8 4.8 M85*1 315.2 224
TSL-1064-120-240Q-D14 240 120*120 14 ±21 4 M85*1 471 345
TSL-1064-150-420Q-D14 420 150*150 14 ±20 5 M85*1 794.44 636.44
257nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-257-45-100Q-D10 100 45*45 10 ±18.7 1 M66*1 200.82 126.35
Optical Glass Material Series
532nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-532-53-100 100 53*53 15 ±25 3.2 M85*1 175.6 127.43
TSL-532-75-163A 163 75*75 10 ±18.9 1.3 M85*1 302.3 167.2
TSL-532-60-100-D10 100 60*60 10 ±26 2.5 M85*1 198.93 120.62
1064nm Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-1064-18-56 56 18*18 10 ±13.3 1 M551/M391 85.64 59.35
TSL-1064-20-56 56 20*20 10 ±13 2.6 M85*1 79.85 59.85
TSL-1064-60-107-D10 107 60*60 10 ±23.6 1.7 M79*1 229 135.68
TSL-1064-90-190 190 90*90 18 ±14 1 M85*1 337.03 166.38
TSL-1064-56-125 125 56*56 15 ±25 5.7 M85*1 195.8 151.39
TSL-1064-73-163A 163 73*73 15 ±18.2 1 M85*1 324.71 207.71
TSL-1064-65-115 115 65*65 12 ±25 2 M85*1 215.43 136.43
CO₂ Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-9.4-9-40-D14 40 9*9 14 ±9 3 M80*1 121.92 36.18
TSL-9.4-30-52 52 30*30 20 ±21.8 4.5 M85*1 75.87 32.26
TSL-9.4-50-100Z-D20 100 50*50 20 ±20.8 2.7 M85*1 187.84 118.84
TSL-9.4-50-75Z-D14 75 50*50 14 ±27.8 2.8 M85*1 131.95 68.95
TSL-9.6-50-100G 100 50*50 15 ±25 3 M85*1 174.6 106.1
TSL-10.6-50-100-D20-LP 100 50*50 20 ±20.3 2.3 M85*1 168.06 89.96
Other Telecentric Series
Model Effective Focal Length (mm) Scanning Area (mm) Entrance Pupil (mm) Scan Angle (°) Telecentric Angle (°) Thread Interface Flange Distance (mm) Working Distance (mm)
TSL-355-635-50-120-V2 120 50 6 ±16.7 1.8 M85*1 107.02 65.52






  • Previous:
  • Next:

  • Write your message here and send it to us

    PRODUCT CATEGORIES

    Wavelength has been focused on providing high precision optical products for 20 years